Electrical Cabinet
Indoors
Recent attachments
2 files
=======================================================
ELECTRICAL INSTALLATION APPROVAL CERTIFICATE
=======================================================
Certificate No. : CERT-ELEC-2026-00117
Issue Date : 10 February 2026
Valid Until : 10 February 2031
-------------------------------------------------------
PROPERTY INFORMATION
-------------------------------------------------------
Property Address : 14 Maplewood Drive, Riverside Falls, OH 45001
Owner : Demo Home Owner
Property Type : Residential Single Family
-------------------------------------------------------
INSTALLATION DETAILS
-------------------------------------------------------
Description : Main Electrical Load Center / Distribution Panel
Cabinet ID : EC-MAIN-01
Location : Utility Room
Manufacturer : Eaton Corporation
Model : BR3040L200PG
Serial No. : EAT-2019-883741
Installed : 14 March 2019
Rated Capacity : 200 Ampere, 120/240V, Single Phase, 60Hz
-------------------------------------------------------
CERTIFYING AUTHORITY
-------------------------------------------------------
Inspecting Body : Riverside Falls Building & Safety Dept.
Department Ref. : RFBSD-ELEC-2026-0289
Approved By : Patricia L. Donovan
Title : Chief Electrical Inspector
License No. : CEI-OH-10492
Phone : +1 (555) 200-4400
-------------------------------------------------------
BASIS OF APPROVAL
-------------------------------------------------------
This installation has been inspected and tested in
accordance with the following standards and regulations:
- National Electrical Code (NEC) 2023 Edition
- NFPA 70 Residential Electrical Requirements
- Ohio Residential Building Code, Chapter 27 (Electrical)
- UL Listed Equipment Standard (UL 67 - Panelboards)
Inspection conducted by licensed inspector:
James R. Holloway, Holloway Electrical Services LLC
License No. EL-78432-OH
Inspection Report Ref. INS-2026-04-0042
-------------------------------------------------------
APPROVAL STATEMENT
-------------------------------------------------------
This certificate confirms that the electrical installation
described above has been inspected, tested, and found to
comply with all applicable codes and standards in effect
at the time of inspection.
The installation is hereby APPROVED for continued
residential use.
This certificate does not cover any modifications,
additions, or alterations made after the date of issue.
Any such changes must be separately inspected and approved.
-------------------------------------------------------
CERTIFICATE STATUS
-------------------------------------------------------
Status : APPROVED
Issued : 10 February 2026
Expires : 10 February 2031
Next Inspection : On or before 10 February 2031
-------------------------------------------------------
AUTHORIZED SIGNATURE
-------------------------------------------------------
Signed : Patricia L. Donovan
Title : Chief Electrical Inspector
Date : 10 February 2026
[ RIVERSIDE FALLS BUILDING & SAFETY DEPARTMENT — OFFICIAL SEAL ]
=======================================================
END OF APPROVAL CERTIFICATE
=======================================================
Text
ElectricalCabinet_ApprovalCertificate.txt
=======================================================
ELECTRICAL CABINET INSPECTION REPORT
=======================================================
Report Number : INS-2026-04-0042
Inspection Date : 10 February 2026
Property : Demo Home, 14 Maplewood Drive, Riverside Falls
Inspected By : James R. Holloway
License No. : EL-78432-OH
Company : Holloway Electrical Services LLC
Phone : +1 (555) 304-7821
Email : inspections@hollowayelectrical.com
-------------------------------------------------------
CABINET DETAILS
-------------------------------------------------------
Cabinet ID : EC-MAIN-01
Location : Utility Room
Manufacturer : Eaton Corporation
Model : BR3040L200PG
Serial No. : EAT-2019-883741
Installed : 14 March 2019
Rating : 200A / 120/240V Single Phase
Panel Type : Load Center (Main Breaker)
Number of Slots : 30 spaces (max 40 circuits)
-------------------------------------------------------
INSPECTION CHECKLIST
-------------------------------------------------------
[PASS] Main breaker condition and rating 200A OK
[PASS] Panel cover and enclosure integrity No damage
[PASS] Labeling of all circuits All labeled
[PASS] Grounding and bonding connections Secure
[PASS] Neutral bar connections Tight, no corrosion
[PASS] Ground bar connections Tight, no corrosion
[PASS] Wire gauge vs. breaker rating (all circuits) Compliant
[PASS] No double-tapped breakers None found
[PASS] No signs of overheating or burn marks None found
[PASS] Arc fault (AFCI) breakers where required Installed in bedrooms
[PASS] Ground fault (GFCI) protection Kitchen/Bath/Garage OK
[PASS] Breaker seating and alignment All seated correctly
[PASS] Cable management and strain relief Adequate
[PASS] Clearance around panel (min. 36 inches) Compliant
[WARN] Spare capacity Only 2 slots remaining
-------------------------------------------------------
OBSERVATIONS & NOTES
-------------------------------------------------------
1. Panel is nearing full capacity with only 2 breaker slots remaining.
Recommend planning a panel upgrade or sub-panel installation if
additional circuits are needed in the future (e.g. EV charger).
2. Circuit #14 (Garage Outlets) breaker shows minor age-related
discoloration. No immediate action required, but recommend
monitoring and replacing at next inspection if discoloration
increases.
3. All AFCI and GFCI devices tested and functioning correctly.
4. Panel directory card updated and laminated during inspection.
-------------------------------------------------------
SUMMARY
-------------------------------------------------------
Overall Status : PASS (with advisory)
Next Inspection : February 2031 (5-year interval)
This panel meets current National Electrical Code (NEC) requirements
for a residential installation of this type and age. No immediate
corrective action is required.
-------------------------------------------------------
INSPECTOR SIGNATURE
-------------------------------------------------------
Signed : James R. Holloway
Date : 10 February 2026
Stamp : [ HOLLOWAY ELECTRICAL SERVICES — LIC. EL-78432-OH ]
=======================================================
END OF INSPECTION REPORT
=======================================================
Text
ElectricalCabinet_InspectionReport.txt
1
Tasks total
0
Completed
0
Overdue
2
Attachments
2/10/2031
Next due
Inspection
Open5-year inspection interval
Due: 2/10/2031